Table 13. CH 2 Risetime

Calibration Procedure For Dual Trace Amplifiers Am-6880/U (Type 7A18), Types 7A18A, 7A18A With Option 6, And Am-6785/U (Type 7A26) Page Navigation
  12    13    14    15    16  17
img
. . . .
TB 9-6625-2099-24
b. Adjustments
(1) Adjust HF C1336, HF R1336, HF C1432, HF C1435, HF R1435, HF C1531, HF
R1531, HF C1345, and HF R1345 (fig. 3) for optimum front corner and flat top (R).
(2) Adjust HF C2336, HF R2336, HF C2432, HF C2435, HF R2435, HF C2531, HF
R2531, HF C2345, and HF R2345 (fig. 3) for optimum front corner and flat top (R).
15. Final Procedure
a. Deenergize and disconnect all equipment.
b. Annotate and affix DA label/form in accordance with TB 750-25.