TB 9-6625-2155-35
b. Adjustments
(1) Adjust A3A1R2 (fig. 16) for an indication of +22.00 V dc on digital
(2) Adjust A3A3R50 (fig. 17) for an indication of 20.000 V dc on digital multimeter.
No further adjustments can be made (R).
a. Deenergize and disconnect all equipment.
b. Annotate and affix DA label/form in accordance with TB 750-25.