TB 9-6625-2163
a. Performance Check
(1) Press PUSH TO LOCK switch and turn to LOCK position.
(2) Set FUNCTION, MODE, and CODE switches and RTS menu functions as
listed in table 4 below. ACCEPT and REJECT lamps will indicate as listed.
Test instrument
Radar test set
Test instrument
Menu 3
Menu 3
ACCEPT/REJECT
FUNC
MODE
CODE
CODES
REPLY SIGNAL
lamp
SYSTEM
2
7777
M2: 0000
SIF
REJECT
SYSTEM
2
0000
M2: 0000
SIF
ACCEPT
SYSTEM
2
1111
M2: 0000
SIF
REJECT
SYSTEM
2
1111
M2: 1111
SIF
ACCEPT
SYSTEM
2
2222
M2: 1111
SIF
REJECT
SYSTEM
2
2222
M2: 2222
SIF
ACCEPT
SYSTEM
2
3333
M2: 2222
SIF
REJECT
SYSTEM
2
3333
M2: 3333
SIF
ACCEPT
SYSTEM
2
4444
M2: 3333
SIF
REJECT
SYSTEM
2
4444
M2: 4444
SIF
ACCEPT
SYSTEM
2
5555
M2: 4444
SIF
REJECT
SYSTEM
2
5555
M2: 5555
SIF
ACCEPT
SYSTEM
2
6666
M2: 5555
SIF
REJECT
SYSTEM
2
6666
M2: 6666
SIF
ACCEPT
SYSTEM
2
7777
M2: 6666
SIF
REJECT
SYSTEM
2
7777
M2: 7777
SIF
ACCEPT
EMERG
1
7700
M1: 7700
SIF
REJECT
EMERG
2
7700
M2: 7700
SIF
REJECT
EMERG
3/A
7700
M3/A: 7700
SIF
REJECT
EMERG
C
7700
MC: 7700
SIF
ACCEPT
EMERG
C
7700
MC: 7700
VAR EMERG
REJECT
EMERG
3/A
7700
M3/A: 7700
VAR EMERG
ACCEPT
EMERG
2
7700
M2: 7700
VAR EMERG
ACCEPT
EMERG1
1
7700
M1: 7700
VAR EMERG
ACCEPT
I/P
2
7700
M2: 7700
ID OF POS
ACCEPT
I/P
3/A
7700
M3/A: 7700
ID OF POS
ACCEPT
1Perform
transmitter output power check if emergency mode 1 step produces a flickering ACCEPT light.
b. Adjustments. No adjustments can be made.