TB 9-6625-2185-24
Table 3. Basic Instrument Accuracy - Continued
Synthesizer/level
generator
Display indications (dBm)
output (dBm)
Min
Max
+5.0
+04.87
+05.13
+4.0
+03.88
+04.12
+3.0
+02.89
+03.11
+2.0
+01.90
+02.10
+1.0
+0.91
+01.09
0
-0.08
+00.08
-10
-10.15
-09.85
-20
-20.15
-19.85
-30
-30.21
-29.79
(9) Position synthesizer/level generator controls for a 50 MHz, -86 dBm output and
connect equipment as shown in figure 2, CONNECTION A.
Figure 2. +15 and +25 dBm accuracy equipment setup.
(10) Adjust synthesizer/level generator output level to within RF power amplifier
input operating range. Slowly increase RF power amplifier gain control for a power meter
indication of -5 dBm.
(11) Use precision power measurement technique used in paragraph 8 a (7) through
(12) above; calculate power and record as P2.
9