TB 9-6625-2324-35
Table 2. Minimum Specifications of
Equipment Required
Manufacturer and model
Common name
Minimum use specifications
(part number)
CALIBRATOR
Dc voltage:
John Fluke, Model 5700A/CT
Range: 1 mV to 2.5 V
(p/o MIS-35947); w/
Accuracy: 1 mV, 0.375%
amplifier, John Fluke, Model
1 V, 4%
5725A (5725A)
0.25 and 2.5 V, 1.12%
Ac voltage:
Range: 1 mV to 600 V
Accuracy (%)
Voltage
10 Hz
1.9 mV to 190 V
1.25
40 Hz
1.9 mV
0.75
19 mV
0.5
190 mV to 600 V
0.25
500 Hz
1.9 mV
0.5
100 mV to 100 V
0.125
1 kHz
1 mV
0.5
10 mV
0.25
100 mV to 3 V
0.125
5 kHz
1.9 mV
0.5
19 mV
0.25
190 mV to 190 V
0.125
600 V
0.125
40 kHz
600 V
0.125
50 kHz
100 mV to 100 V
0.125
100 kHz
1.9 mV
1
19 mV
0.25
190 mV to 190 V
0.125
190 kHz
1 mV
1
1.5 MHz
1 mV
1
10 MHz
1 mV
1.25
190 kHz
10 mV
0.25
990 kHz
10 mV
0.5
1.5 MHz
10 mV
1
10 MHz
10 mV
1.25
190 kHz
100 mV to 3 V
0.125
990 kHz
100 mV to 3 V
0.175
1.5 MHz
100 mV to 3 V
0.75
10 MHz
100 mV to 3 V
1.25
Range: -15.2 to +15.1 V dc
John Fluke, Model 8840A/AF
Accuracy: 0.17%
(AN/GSM-64D)
4