Table 8. Variable Pulse 1 Characteristics
Challenge & Tag Generator

Calibration Procedure For Transponder Test Set Model An/Upm-155 Page Navigation
  13    14    15    16    17  18  19    20    21    22    23  
img
. . . . . . . . .
TB 9-6625-2337-24
Use the arrow keys to highlight VP1, ENTR (ON).
(a)
Use the arrow keys to highlight VP1 PW:.
(b)
0.5, ENTR.
(c)
Use the arrow keys to highlight VP1 DLY:.
(d)
10, ENTR.
(e)
Use the arrow keys to highlight VP2 PW:.
(f)
0.5, ENTR.
(g)
Use the arrow keys to highlight VP2 DLY:.
(h)
1, ENTR.
(i)
(24) Set the oscilloscope to measure the period between variable pulse 1 and variable
pulse 2. Verify that the period is within limits listed in table 10.
(25) Repeat technique of (23) and (24) above for remaining rows in table 10. Verify
that the period is within limits listed in table 10.
Table 10. VP1/2 Delay
VP 1
VP1
VP2
VP2
Measurement
Test description
width
delay
width
delay
type
Min
Max
VP1/2 1 s delay
0.5 s
10 s
0.5 s
1 s
0.9 s
1.1 s
Period
VP1/2 100 s delay
0.5 s
10 s
0.5 s
100 s
99.9 s
100.1 s
Period
VP1/2 20 s delay
10 s
10 s
10 s
20 s
19.9 s
20.1 s
Period
10 s
10 s
10 s
20 s
VP1/2 duty cycle
Duty cycle
49 %
51 %
10 s
10 s
10 s
20 s
VP1 10 s delay
9 s
11 s
Delta time 1
10 s
10 s
10 s
20 s
VP2 30 s delay
29 s
31 s
Delta time 2
1
Delay from channel 1 to first pulse on channel 2.
2
Delay from channel 1 to second pulse on channel 2.
(26) Disconnect cable from TI VAR PULSE output and connect it to the TI IFF
VIDEO OUT FIRST REPLY output.
(27) Press TI keys as listed in (a) through (d) below:
Use the arrow keys to highlight OR CHALLENGE, ENTR (YES).
(a)
Use the arrow keys to highlight 1ST REPLY, ENTR (YES).
(b)
Press FUNC and  keys.
(c)
3, ENTR (1st REPLY).
(d)
(28) Set the oscilloscope to first measurement function listed in table 11. Verify that
the oscilloscope indication is within limits listed in table 11.
(29) Repeat technique of (27) through (28) above for remaining rows in table 11 using
settings and connections listed in table 11. Verify that the measurement type is within
limits listed in table 11.
NOTE
Oscilloscope channel 2 connections column indicated the
connection to be used in repeating technique of (29) above.