TB 9-6625-2296-35
(2) Press key sequence listed in (a) through (f) below:
Meters Menu
(a) MODE MTRS .........................
Auxiliary Functions Menu
(b) AUX (F6) .................................
Recall Parameters Menu
(c) MEMORY RCL ......................
(d) FIELD SELECT ⇑ .................
Highlight 10. Factory Defaults
Factory Defaults recall
(e) DATA ENTRY ENTER .........
NOTE
Assure highlighted area indicates YES before proceeding.
Factory Defaults restored
(f) DATA ENTRY ENTER .........
(3) Press key sequence listed in (a) through (m) below:
AF GEN screen
(a) MODE AF GEN.....................
AF Gen Menu
(b) SETUP ...................................
AF Gen # 1 Setup
(c) DATA ENTRY 1 ....................
Wave Form
(d) DATA ENTRY 3 ....................
0 Lvl
(e) DATA ENTRY 7 ....................
Escape
(f) ESC (F6) .................................
AF Gen # 2 Setup
(g) DATA ENTRY 2 ....................
Wave Form
(h) DATA ENTRY 3 ....................
0 Lvl
(i) DATA ENTRY 7 ....................
Escape
(j)
ESC (F6) .................................
AF Output Setup
(k) DATA ENTRY 5 ....................
To Speaker On
(l) DATA ENTRY 2 ....................
Return
(m) Ret (F5) ..................................
(4) Connect multimeter INPUT HI and LO to TI AUDIO OUT. Set multimeter to
measure volts dc.
(5) Press FIELD SELECT ⇓ key to select LEVEL and press DATA ENTRY
ENTER key. Press DATA ENTRY 3 . 1 and ENTER keys.
(6) Press FIELD SELECT ⇑ key to select GEN 1 and press DATA ENTRY
ENTER key to set GEN 1 On.
(7) If multimeter does not indicate 0.000 .01 V dc adjust A24R23 (fig. 2) as
close as possible.
15