TB 9-6625-2296-35
Factory Defaults recall
(e) DATA ENTRY ENTER ..........
NOTE
Assure highlighted area indicates YES before proceeding.
Factory Defaults restored
(f) DATA ENTRY ENTER ..........
(2) Connect measuring receiver sensor module to TI T/R. Connect measuring
receiver MODULATION OUTPUT/AUDIO INPUT to audio analyzer INPUT HIGH.
(3) Set measuring receiver to measure AM, low pass filter 3 kHz, high pass
filter 50 Hz, and PEAK /2 detector selected.
(4) Press key sequence listed in (a) through (h) below:
RF Gen Display
(a) MODE RF GEN ......................
Gen Menu
(b) SETUP .....................................
RF Gen Setup
(c) DATA ENTRY 5 ......................
RF Gen Freq
(d) DATA ENTRY 1 ......................
750 kHz
(e) DATA ENTRY 7 5 0 K ............
RF Gen Level
(f) DATA ENTRY 2 ......................
0 dBm
(g) DATA ENTRY 0 ENTER .......
Return
(h) Ret (F5) ....................................
(5) Record measuring receiver indication as residual AM.
(6) Repeat (4) (e) and (5) above for RF generator frequencies of 10 and 900 MHz.
(7) Press DATA ENTRY 1 2 1 . 1 M keys (121.1 MHz).
(8) Press Source (F4) (Audio Frequency Source), DATA ENTRY 1, and DATA
ENTRY ENTER keys to set source to 1 and AM.
(9) Set measuring receiver to measure AM, low pass filter 3 kHz, high pass
filter 50 Hz and PEAK /2 detector selected. Set audio analyzer to measure distortion in
percent.
(10) Press More (F6), A Freq (F1) and press DATA ENTRY keys to set AF FREQ
to 100 Hz, then press DATA ENTRY ENTER key.
(11) Press More (F6) key twice, Mod (F5) and DATA ENTRY keys to set
MODULATION to 50%, then press DATA ENTRY ENTER keys.
(12) Audio analyzer indication will be less than specified in table 16 for current
TI setting.
(13) Repeat (7) and (9) through (12) for remaining settings listed in table 16.
NOTE
Pressing More (F6) will scroll various options on the bottom of
the display. The options will change the functions assigned to
the F1 through F6 function keys. This may be necessary to
obtain the Freq (F2), Mod (F5), and A Freq (F1) options
required in the following tests.
48