Table 4. Harmonic Rejection - Continued

Calibration Procedure For High Power Tunable Band Pass Filter Rodale Electronics, Inc. Model 13589299 Page Navigation
  2    3    4    5    6  7
img
. .
TB 9-5915-215-40
Table 4. Harmonic Rejection - Continued
Signal
generator or
Test instrument
synthesized
Spectrum analyzer
signal
generator
Center
Thumb
Harmonic
Frequency
frequency
Level indication
wheel
#
(Hz)
(Hz)
(dB)
15
---------------
150.0  M
150.0 M
Ref
50
---------------
2
300.0  M
300.0 M
50
---------------
3
450.0  M
450.0 M
50
---------------
4
600.0  M
600.0 M
161
---------------
270.0  M
270.0 M
Ref
50
---------------
2
540.0  M
540.0 M
50
---------------
3
810.0  M
810.0 M
50
---------------
4
1.08 G
1.08 G
17
---------------
600.0  M
600.0 M
Ref
50
---------------
2
1.2  G
1.2 G
50
---------------
3
1.8  G
1.8 G
50
---------------
4
2.4  G
2.4 G
18
---------------
1000
M
1000
M
Ref
50
---------------
2
2.0  G
2.0 G
50
---------------
3
3.0  G
3.0 G
50
---------------
4
4.0  G
4.0 G
1
Replace signal generator with synthesized signal generator.
(9) Set synthesized signal generator RF OUTPUT to off and disconnect
equipment setup.
b. Adjustments. No adjustments can be made.
10. Final Procedure
a. Deenergize and disconnect all equipment.
b. Annotate and affix DA label/form in accordance with TB 750-25.