Table 5. Continuity M439 Charge to J2-x, Tube Select.
Table 7. Continuity J5-Ctr to J1-x.

Calibration Procedure For Intertek, Remote Rocket Assembly Interface Test Set, Pn 7310-0100 Page Navigation
  1    2    3    4  5  6    7    8    9    10  
img
. . . . . .
TB 9-6625-151-40
(7) Set TI S4 to M433. Set SW1 Tube Select switch to position 1.
(8) Connect test lead to TI fuze module M433 CHG (fig. 2) and measure resistance
to J2-A. MULTIMETER will indicate <0.5 Ω.
Figure 2. TI Front Panel J1.
(9) Set TI SW1 Tube Select switch to position 20.
(10) Measure resistance between connector TI J1 pin Z (fig 2) and first test point
listed in table 6. MULTIMETER will indicate as listed.
(11) Repeat technique of (10) above for remaining J1 test points and limits in
table 6.
Table 6. Continuity Loads J1-Z to J1-x.
Test point
Multimeter
Min Ω
Max Ω
J1-pin
A
3.8
4.7
B
3.8
4.7
C
3.8
4.7
D
3.8
4.7
E
3.8
4.7
F
3.8
4.7
G
3.8
4.7
H
3.8
4.7
J
3.8
4.7
K
3.8
4.7
L
3.8
4.7
M
3.8
4.7
N
3.8
4.7
P
3.8
4.7
R
3.8
4.7
S
3.8
4.7
T
3.8
4.7
U
3.8
4.7
V
3.8
4.7