Figure 9. 10 V 40 mSec Ramp.

Calibration Procedure For Intertek, Remote Rocket Assembly Interface Test Set, Pn 7310-0100 Page Navigation
  12    13    14    15    16  17
TB 9-6625-151-40
(12) Depress and release TI S2 Timer Reset. Observe timer shows 0.000.
(13) Depress and release S8 Reset. Observe all Motor Energy LED's are Off.
(14) Depress and hold for 5 seconds S3 Fuze Discharge switch.
(15) Depress and release FUNCTION GENERATOR #1 trigger switch. Observe TI
Time Out LED remains on for duration of TOF. Observe Timer displays between 22.000
and 34.000 sec.
b. Fuze Confidence M433
(1) Set TI S4 to M433. Set SW1 Tube Select switch to position 1.
(2) Depress and release S2 Timer Reset. Observe timer shows 0.000.
(3) Depress and release S8 Reset. Observe all Motor Energy LED's are Off.
(4) Depress and hold for 5 seconds S3 Fuze Discharge switch.
(5) Depress and release FUNCTION GENERATOR #1 trigger switch. Observe TI
Time Out LED remains on for duration of TOF. Observe Timer displays between 0.450
and 0.750 sec.
(6) Set FUNCTION GENERATOR #1 and # 2 outputs Off.
c. Adjustments. No adjustments can be made.
14. Final Procedure
a. De-energize and disconnect all equipment.
b. Annotate and affix DA label 80 in accordance with TB 750-25.