TB 9-6625-2069-35
Test instrument
HIL data
(V)
indications (dc)
or LOL data
(-V)
Min
Max
0.49 1
430
mV1
550
mV1
0.99
920
mV
1060
mV
1.99
1.900
V
2.08
V
2.99
2.88
V
3.10
V
3.99
3.86
V
4.12
V
7.99
7.78
V
8.20
V
9.99
9.74
V
10.24
V
10 2
9.70
V
10.30
V
13
12.64
V
13.36
V
17
16.56
V
17.44
V
19.9
19.40
V
20.40
V
1When
checking LOL data, all voltage indications will be negative.
2When
checking CHANNEL A, press 1kΩ/50 Ω pushbutton to 1kΩ and CHANNEL B, press 1kΩ/50 Ω pushbutton to 50 Ω
and visa versa when checking CHANNEL B.
NOTE
When checking HIL voltage, leave LOL at 0.0 V.
(5) Press pushbuttons and enter data as listed in (a) through (d) below (both
channels for option 020).
CHANNEL A for 50 Ω, NORM.
(a)
CHANNEL B for 50 Ω, NORM.
(b)
(c)
LOL to - 0.10 V.
(d)
HIL to 0 V.
(6) Multimeter will indicate between -48 and -152 mV.
(7) Repeat technique of (5) and (6) above using data listed in table 11. Multimeter
will indicate within limits specified.
NOTE
When checking LOL voltage leave HIL at 0.0 V.
(8) Press CHANNEL A and CHANNEL B 1kΩ/50 Ω pushbuttons to 50 Ω.
(9) Press LOL pushbutton to -.1 V.
(10) Repeat (1) through (9) above for OUTPUT B (option 020 only).
b. Adjustments. No adjustments can be made.
12