TB 9-6625-2135-35
Performance specifications
Accuracy: (% of reading + digits)
Test instrument parameters
4 1/2 digits (1999.9 maximum display)
Models 3565A and 3465B
Dc Voltage
Range: 0 to 1000 V (in 6 ranges)
Range:
Accuracy:
20 mV
0.03 + 2
200 mV to 200 V
0.02 + 1
1000 V
0.025 + 1
Ac Voltage
Range: 0 to 500 V (in 5 ranges)
Range:
Accuracy:
200 mV to 200 V 1
40 Hz to 10 kHz 0.15 + 5
10 to 20 kHz
0.50 + 15
500 V
40 Hz to 1 kHz 0.15 + 5
1 to 2 kHz
0.50 + 5
Ac current2
Range: 0 to 2000 mA (in 5 ranges)
Range:
Accuracy:
200 A to 20 mA
40 Hz to 2 kHz 0.4 + 5
2 to 10 kHz
0.25 + 5
10 to 20 kHz
0.6 + 15
200 mA
40 Hz to 1 kHz 0.8 + 5
1 to 2 kHz
0.65 + 4
2000 mA
40 Hz to 1 kHz 0.8 + 5
Dc Current
Range: 0 to 2000 mA (in 5 ranges)
Range:
Accuracy:
200 A to 2 mA
0.07 + 1
20 mA
0.11 + 1
200 and 2000 mA
0.6 + 1
Range: 0 to 20 M Ω (in 6 ranges)
Range:
Accuracy:
200Ω
0.02 + 2
2 through 2000 kΩ
0.02 + 1
20 M Ω
0.1 + 1
Model 3466A
Dc voltage
Range: 0 to 1200 V (in 6 ranges)
Range:
Accuracy:
20 mV
0.05 + 3
200 mV
0.04 + 2
2 and 20 V
0.03 + 1
200 V
0.035 + 1
1200 V
<700 V 0.035 + 1
1200 V
>700 V 0.055 + 1