CALIBRATION PROCEDURE FOR MEASURING SYSTEM
SECTION I. IDENTIFICATION AND DESCRIPTION

Calibration Procedure For Measuring System, Td-1209/U (Model 5300A); 50 Mhz Universal Counter, Td-1211/U (Model 5302A); 10 Mhz Counter (Model 5301A); 500 Mhz Counter (Model 5303A); 525 Mhz Counter (Model 5303B); Timer/Counter (Model 5304A) And Multimeter/Counter (Model 5306A) Page Navigation
  1  2  3    4    5    6    7  
img
. . . . . . . . . . . . . . . . . . . . . . . .
*TB 9-6625-2215-24
DEPARTMENT OF THE ARMY TECHNICAL BULLETIN
CALIBRATION PROCEDURE FOR
MEASURING SYSTEM, TD-1209/U (HP 5300A);
50 MHz UNIVERSAL COUNTER, TD-1211/U (HP 5302A);
10 MHz COUNTER (HP 5301A); 500 MHz COUNTER
(HP 5303A); 525 MHz COUNTER (HP 5303B);
TIMER/COUNTER (HP 5304A) AND
MULTIMETER/COUNTER (HP 5306A)
Headquarters, Department of the Army, Washington, DC
11 July 2014
Distribution Statement A: Approved for public release, distribution is unlimited.
REPORTING OF ERRORS AND RECOMMENDING IMPROVEMENTS
You can improve this manual. If you find any mistakes or if you know of a way to improve these
procedures, please let us know.  Mail your letter or DA Form 2028 (Recommended Changes to
Publications and Blank Forms) directly to: Commander, U.S. Army Aviation and Missile Command,
ATTN: AMSAM-MSS-LP, Redstone Arsenal, AL 35898-5000. A reply will be furnished to you.
You  may  also  send  in  your  comments  electronically  to  our  E-mail  address:
2028@redstone.army.mil or by fax 256-842-6546/DSN 788-6546.  For the World Wide Web use:
https://amcom2028.redstone.army.mil. Instructions for sending an electronic 2028 can be found at
the back of this manual.
Paragraph
Page
SECTION
I.
IDENTIFICATION AND DESCRIPTION
Test instrument identification ...........................
1
2
Forms, records, and reports ................................
2
3
Calibration description .......................................
3
3
II.
EQUIPMENT REQUIREMENTS
Equipment required ............................................
4
4
Accessories required............................................
5
4
III.
CALIBRATION PROCESS FOR MEASURING
SYSTEM, TD-1209/U (HP 5300A) AND
50 MHz UNIVERSAL COUNTER
TD-1211/U (HP 5302A)
Preliminary instructions.....................................
6
5
Equipment setup .................................................
7
6
Time base stability ..............................................
8
6
Sensitivity ............................................................
9
6
Final procedure....................................................
10
8
_________
*This bulletin supersedes TB 9-6625-2215-24, dated 29 June 2009.