TB 9-6625-2296-35
(36) Press (F3) (Scan) and DATA SCROLL arrow keys to select 1 kHz scan width.
Press DATA ENTRY ENTER key. Displayed signal peak will be within 3 dBm of center
reference established in (35) above.
(37) Press (F3) (Scan) and DATA SCROLL arrow keys to select 10 kHz scan width.
Press DATA ENTRY ENTER key. Displayed signal peak will be within 2 dBm of center
reference established in (35) above.
(38) Press (F3) (Scan) and DATA SCROLL arrow keys to select 1 MHz scan width.
Press DATA ENTRY ENTER key. Displayed signal peak will be within 2 dBm of center
reference established in (35) above.
(39) Press (F3) (Scan) and the DATA SCROLL arrow keys to select 50 MHz scan
width. Press DATA ENTRY ENTER key. Displayed signal peak will be within 3 dBm of center
reference established in (35) above.
b. Adjustments
(2) Press key sequence listed in (a) through (f) below:
Meters Menu
(a) MODE MTRS ..........................
Auxiliary Function Menu
(b) AUX (F6) ..................................
Recall
(c) MEMORY RCL .......................
(d) FIELD SELECT ⇑ ..................
Highlight 10. Factory Defaults
Factory Defaults recall
(e) DATA ENTRY ENTER ..........
NOTE
Assure that the highlighted area indicates YES before
proceeding to next step.
Factory Defaults restored
(f) DATA ENTRY ENTER ..........
(3) Press key sequence listed in (a) through (f) below:
(a) MODE RF GEN ......................
Displays Menu
(b) F1 (Disp) ..................................
Full Analyzer Display
(c) 2 (Full Anlz) ............................
Select Level Display
(d) F3 (Level).................................
0 dB level
(e) DATA ENTRY 0 ENTER .......
Select Scan Display
(f) F5 (Scan)..................................
(4) Press DATA SCROLL arrow keys to toggle between 20 kHz and 200 kHz while
adjusting ANALYZER RF A5 ANALZR CENTER (fig. 1) for best centered compromise.
(5) Press key sequence listed in (a) through (h) below:
(a) FIELD SELECT ⇑ ..................
Highlight SOURCE
Set MOD to FM
(b) DATA SCROLL arrow ...........
38