TB 9-6625-2337-24
Table 39. Modulation Characteristics - Continued
TI
Test description
Settings
Measurement type
Minimum
Maximum
GTC LONG P1
Use the arrow keys to highlight
Delta time from 2d
14.25 μs
15.75 μs
GTC SHORT:
SPACE
to 3d pulse
ENTR (OFF)
Use the arrow keys to highlight
GTC LONG:
ENTR (ON)
GTC LONG P2
----------------------------------------
Delta time from 2d
28.5 μs
31.5 μs
SPACE
to 4th pulse
GTC LONG P3
----------------------------------------
Delta time from 2d
57.0 μs
63.0 μs
SPACE
to 5th pulse
GTC LONG P4
----------------------------------------
Delta time from 2d
114.0 μs
126.0 μs
SPACE
to 6th pulse
GTC LONG P5
----------------------------------------
Delta time from 2d
228.0 μs
252.0 μs
SPACE
to 7th pulse
GTC LONG P6
----------------------------------------
Delta time from 2d
456.0 μs
504.0 μs
SPACE
to 8th pulse
GTC LONG P1
----------------------------------------
Width pulse 3
400.0 ns
600.0 ns
PW
GTC LONG P2
----------------------------------------
Width pulse 4
400.0 ns
600.0 ns
PW
GTC LONG P3
----------------------------------------
Width pulse 5
400.0 ns
600.0 ns
PW
GTC LONG P4
----------------------------------------
Width pulse 6
400.0 ns
600.0 ns
PW
GTC LONG P5
----------------------------------------
Width pulse 7
400.0 ns
600.0 ns
PW
GTC LONG P6
----------------------------------------
Width pulse 8
400.0 ns
600.0 ns
PW
GTC SHORT P1
Delta time from 2d
14.25 μs
15.75 μs
1
1
to 3d pulse
Press FUNC,
SPACE
2, ENTR (AUX
MODULATION)
Use the arrow keys to highlight
CHALLENGE:
ENTR (ON)
Use the arrow keys to highlight
ISLS:
ENTR (OFF)
Use the arrow keys to
highlight RF:
95, ENTR (-95)
Use the arrow keys to
highlight AUX:
0, ENTR (-0)
Use the arrow keys to highlight
GTC SHORT:
ENTR (ON)
Use the arrow keys to highlight
GTC LONG:
ENTR (OFF)
See footnote at end of table.
62