TB 9-6625-2337-35
Table 12. Challenge/Tag Generator - Continued
Channel 2
measurement
Test description
TI setting
type
Min
Max
FUNC, ↑
≤0.1 s
MODE4 Rise Time
Rise Time
----------
2, ENTR (CHALLENGES)
Use the arrow keys to highlight M4:
ENTR until (SYNC), is displayed
Use the arrow keys to highlight M2:
ENTR (OFF)
Use the arrow keys to highlight MC:
ENTR (OFF)
Use the arrow keys to highlight S2:
ENTR (OFF)
Use the arrow keys to highlight S3:
ENTR (OFF)
Use the arrow keys to highlight S4:
ENTR (OFF)
≤0.1 s
MODE4 Fall Time
--------------------------------------
Fall Time
----------
MODE4 5 V Lvl
--------------------------------------
Top
4.9 V
5.1 V
MODE4 Overshoot
--------------------------------------
Overshoot
.1 %
5%
MODE4 .5 s PW
--------------------------------------
Width
470 ns
530 ns
1.95 s
2.05 s
S1 TO S2 DLY
Use the arrow keys to highlight
Period
(S1: ON)
Use the arrow keys to highlight
(S2: ON)
Use the arrow keys to highlight
(S3: ON)
Use the arrow keys to highlight
(S4: ON)
3.95 s
4.05 s
S1 TO S3 DLY
Use the arrow keys to highlight
Period
(S2: OFF)
5.95 s
6.05 s
S1 TO S4 DLY
Use the arrow keys to highlight
Period
(S3: OFF)
7.93 s
8.07 s
Period
S1 TO S5 DLY
Use the arrow keys to highlight
(S4: OFF)
Use the arrow keys to highlight
(S5: ON)
(5) Press TI keys as listed in (a) through (h) below:
(a)
Use the arrow keys to highlight (S5: OFF).
(b)
Use the arrow keys to highlight (M4:).
(c)
ENTR.
(d)
Use the arrow keys to highlight (WORD A).
(e)
Use the arrow keys to highlight (S1: ON).
(f)
Use the arrow keys to highlight (S2: ON).
(g)
Use the arrow keys to highlight (S3: ON).
(h)
Use the arrow keys to highlight (S4: ON).
(6) Use the oscilloscope delta time markers to measure the first and second pulses of
WORD A.
21