TB 9-6695-293-50
(4) Press CLEAR REF WBND soft key.
(5) Repeat technique of (2) through (4) above for the remaining output levels listed
Test instrument
Output level
Output level
Output level
3.0 V
1.0 V
300 mV
Output
Flatness
Limits
Flatness
Limits
Flatness
Limits
error
error
error
(%)
(%)
(%)
10 Hz
0.3000
---
---
---
---
30 Hz
0.1000
---
---
---
---
10 kHz
0.1000
0.1000
0.100
120 kHz
0.1000
0.1000
0.100
500 kHz
0.1001
0.1003
0.101
2 MHz
0.1001
0.1003
0.101
5 MHz
0.2001
0.2003
0.201
10 MHz
0.2001
0.2003
0.201
20 MHz
0.4001
0.4003
0.401
30 MHz
1.0001
1.0003
1.001
Test Instrument
Output level
Output level
Output level
100 mV
30 mV
10 mV
Output
Flatness
Limits
Flatness
Limits
Flatness
Limits
error
error
error
(%)
(%)
(%)
10 kHz
0.100
0.10
0.10
120 kHz
0.100
0.10
0.10
500 kHz
0.103
0.11
0.13
2 MHz
0.103
0.11
0.13
5 MHz
0.203
0.21
0.23
10 MHz
0.203
0.21
0.23
20 MHz
0.403
0.41
0.43
30 MHz
1.003
1.01
1.03
Test instrument
Output level
Output level
3 mV
1 mV
Output
Flatness
Limits
Flatness
Limits
error
error
(%)
(%)
10 Hz
0.10
0.10
120 kHz
0.10
0.10
500 kHz
0.20
0.50
2 MHz
0.20
0.50
5 MHz
0.40
0.70
10 MHz
0.40
0.70
20 MHz
0.60
0.90
30 MHz
1.60
3.00
31