TB 9-6695-298-35
a. Performance Check
NOTE
Do not perform power supply check if all other parameters
are within tolerance.
(1) Measure the +5 V power supply with the digital multimeter by connecting the
+ (positive) lead to the +S terminal and the -(negative) lead to the -S terminal of POWER
(2) Digital multimeter will indicate between +4.95 and +5.05 V dc; if not, perform
b(l) below.