TB 9-4920-463-24
(8) Use or keys to move cursor (dotted line) to 1800 RPM trace.
(9) TI readout, at top of display, will indicate peak signal is 0.80 0.08 IPS at 1800 5 RPM.
b. Adjustments. None
a. Performance Check
(1) Press TI keys as listed in (a) through (c) below:
(a) TRACK.
(b) [MORE] to select 4 blades.
(c) START.
(2) Aim Strobex at rotor disk on Vibrex tester 11A and pull trigger.
(3) Stem of "h" at center of rotor disk will indicate the pattern as shown in figure 6 below.
(4) Release Strobex trigger.
(5) Press TI STOP key.
b. Adjustments.