TB 9-4935-552-50-2
Figure 3. Vertical filament image.
f. Manually
rotate the TI
prism until the
filament is
horizontal, figure 4. Adjust the
gimbal mounts control to recenter the image as required.
Figure 4. Horizontal filament image.
g. Observe the filament image. The filament image should be defined clearly enough
to be readable to within 1/2 reticle division. If the image needs focusing, go to 10a(1).
h. Position the top
edge of the
image at
+10 on the
reticle, figure 4.
i. Manually rotate the filament image 180 degrees cw and record the reticle position of
the top edge of the image.
j. Repeat step i three times. Each recorded value shall be between +6 and +14. If out
of tolerance, proceed to step 10b(1).
9