CALIBRATION PROCEDURE FOR FREQUENCY COUNTER
Forms, Records, and Reports

Calibration Procedure For Frequency Counter, Model 5340A And Mircrowave Frequency Counter Td-1225A(V)1/U (Model 5342A/H14), Td-1225A(V)2/U (Model 5342A/H16) And, Models 5342A And 5343A Page Navigation
  1  2  3    4    5    6    7  
img
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TB 9-6625-2021-24
Paragraph
Page
III.
CALIBRATION PROCESS FOR FREQUENCY
COUNTER HEWLETT-PACKARD, MODEL
5340A
Preliminary instructions ...........................................
6
5
Equipment setup ....................................................
7
5
Time base stability-option 001 only ......................
8
6
Self-check ................................................................
9
7
10 Hz to 250 MHz frequency and 1 M  input
10
8
sensitivity check .....................................................
10 Hz to 18 GHz frequency and 50  input
11
9
sensitivity check .....................................................
Power supply ..........................................................
12
10
Final procedure ......................................................
13
11
IV. CALIBRATION PROCESS FOR MICROWAVE
FREQUENCY COUNTER TD-1225A(V)1/U
(HEWLETT-PACKARD, MODEL 5342A/H14),
TD-1225A(V)2/U (HEWLETT-PACKARD,
MODEL 5342A/H16) AND HEWLETT-
PACKARD, MODELS 5342A AND 5343A
Preliminary instructions .......................................
14
11
Equipment setup ....................................................
15
12
Time base stability (option 001, H14, H16,
time base 10544A and model 5343A)....................
16
12
Self-check ................................................................
17
14
Frequency and sensitivity check - 10 Hz to
520 MHz..................................................................
18
14
Frequency and sensitivity check - 500 MHz to
18 GHz ....................................................................
19
15
Power supply ..........................................................
20
16
Final procedure ......................................................
21
17
SECTION I
IDENTIFICATION AND DESCRIPTION
1. Test Instrument Identification.
This bulletin provides instructions for the
calibration of Frequency Counter, Hewlett-Packard, Model 5340A and Microwave
Frequency  Counter  TD-1225A(V)1/U  (Hewlett-Packard,  Model  5342A/H14),  TD-
1225A(V)2/U (Hewlett-Packard, Model 5342A/H16) and Hewlett-Packard, Models 5342A
and 5343A. The manufacturers' manuals were used as the prime data sources in compiling
these instructions.  The equipment being calibrated will be referred to as the TI (test
instrument) throughout this bulletin.
a. Model Variations. Variations among models are described in text.
b. Time and Technique. The time required for this calibration is approximately 3
hours, using the microwave technique.