TB 9-6625-2211-24
Test
Instrument
display indications (MHz)
timing markers
Min
Max
1st
1024.800
1025.200
2d
1028.800
1029.200
3rd
1029.800
1030.200
4th
1030.800
1031.200
5th
1034.800
1035.200
8th1
1039.400
1040.600
9th
1044.400
1045.600
1st
1014.400
1015.600
2d
1019.400
1020.600
1Set
SIG GEN FUNCTION switch to SWP r15 MHz and adjust oscilloscope controls as necessary to view 9 timing markers
on CH 2.
b. Adjustments. No adjustments can be made.
a. Performance Check
(1) Position controls as listed in 7 d above.
(2) Connect REPLY VID OUT to oscilloscope Channel 1 input, using video cable
and 75 : termination. Connect SCOPE TRIG OUT to oscilloscope AUX TRIG IN input,
using video cable.
(3) Adjust oscilloscope controls as necessary to view TI reply pulse train.
(4) While observing oscilloscope display and TI REPLIES REPLY INHIB
indicator, set SIF CHAL VID SIF MODE SEL switch to 1 and TRIG SEL DCD MODE
SEL switch to 1. The reply pulse train will disappear from oscilloscope display and the
REPLIES REPLY INHIB indicator will light.
(5) Press and hold BIT (MOM) pushbutton. The reply pulse train will reappear on
oscilloscope display and the REPLIES REPLY INHIB indicator will be extinguished.
(6) With the BIT (MOM) pushbutton pressed, set SIF CHAL VID SIF MODE
SEL switch to 2. The reply pulse train will disappear from oscilloscope display and the
REPLIES REPLY INHIB indicator will light.
(7) With the BIT (MOM) pushbutton pressed, set TRIG SEL DCD MODE SEL
switch to 2. The reply pulse train will reappear on oscilloscope display and the REPLIES
REPLY INHIB indicator will be extinguished.
(8) Repeat (6) above with SIF CHAL VID SIF MODE SEL switch set to 3/A.