• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Dc Offset and Attenuator

Calibration Procedure For Function Generator Sg-1288/G Page Navigation
  20    21    22    23    24  25
img
. .
TB 9-6625-2233-24
Table 15. Dc Offset Accuracy - Continued
Multimeter indications
Offset voltage
(Vdc)
(V)
Min
Max
.1
94.0
mV
106.0
mV
.05
44.5
mV
55.5
mV
.025
19.75
mV
30.25
mV
.01
4.9
mV
15.1
mV
.005
-.05
mV
10.05
mV
.003
-2.03
mV
8.03
mV
17. Final Procedure
a. Deenergize and disconnect all equipment.
b. Annotate and affix DA label/form in accordance with TB 750-25.
26