TB 9-6625-2258-24
(12) Configure measuring receiver to measure frequency.
(13) Remove TI top cover.
(14) Adjust A6R12 (fig. 1) for a measuring receiver frequency indication between
2100 and 2102 MHz (R).
(15) Replace TI top cover and wait 5 minutes before proceeding to (16) below.
(17) Configure measuring receiver to measure frequency.
(18) Remove TI top cover.
(19) Adjust A6R6 (fig. 1) for a measuring receiver frequency indication between 7898
and 7900 MHz (R).
(20) Replace TI top cover and wait 5 minutes before proceeding to (21) below.
(21) Repeat (8) through (20) above until both FREQUENCY RANGE CW F1 and
CW F2 frequencies are within the specified limits.
8