(38) Press FREQUENCY RANGE CW F1 key.
(39) Configure measuring receiver to measure frequency.
(40) Remove TI top cover.
(41) Adjust A7R12 (fig. 2) for a measuring receiver frequency indication between
8100 and 8102 MHz.
Figure 2. A7 or A9 board - component locations.
WARNING
Ensure adjustments are made on the correct board. A7 and A9
(fig. 2) component locations are in the same board position but
affect a different frequency range.
(42) Replace TI top cover.
(43) Press FREQUENCY RANGE CW F2 key and wait 10 seconds for frequency
count to settle.
(44) Adjust A7R6 (fig. 2) for a measuring receiver frequency indication between
12,298 and 12,300 MHz (R).
(45) Replace TI top cover and wait 5 minutes before proceeding to (46) below.