Figure 4. Power Supply - Component Locations.

Calibration Procedure For Peak Power Meter Model 8502A Page Navigation
  14    15    16    17    18  19
img
. . . . .
TB 9-6625-2280-40
Table 5. Power Supply.
Power supply
Test instrument test
Change in
Adjustments
Multimeter indications
voltages
points (fig.4)
voltage
(fig. 4)
(V dc)
LO
HI
Min
Max
(+mV dc)
+5
A2TP11
A2TP9
+4.9
+5.1
5
A2R42
-5.2
A2TP1
A2TP10
-5.0
-5.4
5.2
---
-15
A2TP6
A2TP5
-14.985
-15.015
15
A2R22
+15
A2TP6
A2TP3
+14.955
+15.045
15
---
b. Adjustments. No further adjustments can be made.