(1) Place 720K 3.5 inch floppy disk containing files in external disk drive.
NOTE
TI external drive has 720K format and can only read or write
to a 3.5 inch 720K floppy disk.
(2) At TI display crt screen Press Any Main Panel Key To Begin, press any main
panel key.
(3) Press HELP pushbutton.
(4) Press MORE softkey.
(5) Press STORAGE MAINT. softkey.
(6) Press CHANGE DRIVE softkey.
(7) Press DEFAULT Drive A softkey.
(8) Press MORE softkey.
(9) Press STORAGE MAINT. softkey.
(10) Press COPY FILES softkey.
(11) Adjust CURSORS A control to highlight filename OTDRCODE.EXE 03/13/95.
(12) Press SELECT FILE softkey.
(13) Adjust CURSORS A control to highlight filename OTSFTXTC.DAT 03/13/95.
(14) Press SELECT FILE softkey.
(15) Press COPY SELECTIONS softkey.
(16) Press C: key on keyboard.
NOTE
CURSORS A & B knobs can be used to enter drive letter.
Keyboard is needed for a warm boot of TI to maintain correct
sync established in SECTION III, paragraph 7 b.
(17) Ensure C: appears just below Copy Selected File(S) to: on TI display.
(18) Press START COPY softkey.
(19) Wait for message Copying in Progress PLEASE WAIT to disappear from TI display.
(20) Remove floppy disk from external drive.
(21) On keyboard simultaneously press keys Ctrl, Alt, Del to warm boot TI.
(22) After warm boot of TI, Software Level 1.08a should appear when Press Any
Main Panel Key To Begin screen is displayed.