TB 9-6625-2330-35
(6) Repeat (5) above for remaining levels listed in table 5.
Measuring receiver
Test instrument
indications
DATA ENTRY
(dB)
level
Min
Max
13 dBm
11.5
14.5
10 dBm
8.5
11.5
5 dBm
3.5
6.5
0 dBm
-1.5
1.5
(7) Press TI FUNCTION-CARR LEVEL and DATA ENTRY keys to set TI output
(8) Using standard tuned level measurement techniques, measuring receiver will
indicate within limits specified in table 6 for TI RF power level setting.
(9) Press TI FUNCTION-CARR LEVEL and DATA ENTRY keys to set TI output
level to next value listed in table 6. Measuring receiver will indicate within limits specified
in table 6 for TI RF power level setting.
(10) Repeat (9) above for remaining levels listed in table 6.
Measuring receiver
Test instrument
indications
(dB)
DATA ENTRY
level
Min
Max
0
dBm
-1.5
1.5
-10
dBm
-11.5
-8.5
-20
dBm
-21.5
-18.5
-30
dBm
-31.5
-28.5
-40
dBm
-41.5
-38.5
-50
dBm
-51.5
-48.5
-60
dBm
-61.5
-58.5
-70
dBm
-71.5
-68.5
-80
dBm
-81.5
-78.5
-90
dBm
-91.5
-88.5
-100
dBm
-101.5
-98.5
-110
dBm
-111.5
-108.5
(11) Press TI pushbuttons as listed in (a) through (e) below:
(a) FUNCTION-CARR FREQ.
(b) DATA ENTRY-1300 MHz.