TB 9-6625-2337-24
(i) 14, ENTR (PRF/PRI).
(j) Use the arrow keys to highlight KIT/KIR SELECT:.
(k) ENTR (KIR).
s wide, 5 V pulse with 0
s delay,
trigger mode to external, and slope to negative.
(4) Oscilloscope will indicate within limits listed in first row of table 34.
(5) Repeat technique of (2) through (4) above using remaining setting and limits
TI
Test description
Settings/connection
Measurement type
Minimum
Maximum
KIR EXT TRIG
--------------------------------------
Pulse count
28
28
channel 2
--------------------------
Pulse count
28
28
0.5 s width 1.5 V
channel 2
CHVID 4.5V LVL
Use the arrow keys to highlight
V Top
3.5 V
5.5 V
KIR TRIGGER:
Channel 2
ENTR (INT)
2
Press FUNC,
, ENTR (CHALLENGES)
Use the arrow keys to highlight
M4:
ENTR (SYNC)
Use the arrow keys to highlight
S2:
ENTR (OFF)
Use the arrow keys to highlight
S3:
ENTR (OFF)
Use the arrow keys to highlight
S4:
ENTR (OFF)
CHVID RISE
--------------------------------------
Rise Time
---------------
100 ns
TIME
channel 2
CHVID FALL
--------------------------------------
Fall Time
---------------
150 ns
TIME
channel 2
CHVID
--------------------------------------
Overshoot
---------------
5%
OVERSHOOT
channel 2
CHVID .5 S PW
--------------------------------------
Width
470 ns
530 ns
channel 2
CHVID 168 S
167.5 s
Disconnect Pulse Generator
Delta time channel 1
168.5 μs
from setup. Connect TI
to channel 2
DLY
TRIGGERS M4 PRE OUT to
using a 93 feedthrough
termination.
Move connection from TI KIR
GTC TRIG 4.5 V
V Top
3.5 V
5.5 V
CH VID OUT to TI KIR GTC
LVL
Channel 2
TRIG OUT.
48