TB 9-6625-2337-35
(d)
Use the arrow keys to highlight MAIN FREQ:.
(e)
1010, ENTR (1010 MHZ).
Press FUNC, ↑.
(f)
(g)
11, ENTR (MAIN MODULATION).
(h)
Use the arrow keys to highlight CW:.
(i)
ENTR (ON).
(j)
Use the arrow keys to highlight RF:.
(k)
0, ENTR (-0).
Press FUNC, ↑.
(l)
(m)
(3) Set spectrum analyzer as listed in (a) through (e) below.
(a)
(b)
Span 20 MHz.
(c)
(d)
(e)
Peak Search.
(4) Verify that the spectrum analyzer indication is within limits listed in table 36.
(5) Repeat technique of (2) (e), (3) and (4) for remaining rows and settings in
TI
Spectrum analyzer
Test description
Settings
Measurement type
Minimum
Maximum
1010 MHZ MAIN
--------------------------------------
Marker frequency
1.0095 G
1.0105 G
OUT
1030 MHZ MAIN
Use the arrow keys to highlight
1.0295 G
1.0305 G
OUT
MAIN FREQ:
1030, ENTR (1030 MHZ)
1090 MHZ MAIN
1090, ENTR (1090 MHZ)
1.0895 G
1.0905 G
OUT
1110 MHZ MAIN
1100, ENTR (1100 MHZ)
1.0995 G
1.1105 G
OUT
(6) Press TI keys as listed in (a) through (n) below:
(a)
1030, ENTR (1030 MHZ).
Press FUNC, ↑.
(b)
(c)
14, ENTR (PRF/PRI).
(d)
Use the arrow keys to highlight PRF:.
(e)
300, ENTR (300 PPS).
Press FUNC, ↑.
(f)
(g)
2, ENTR (CHALLENGES).
(h)
Use the arrow keys to highlight M2:.
(i)
ENTR, (OFF).
Press FUNC, ↑.
(j)
(k)
56 CHANGE 1