TB 9-6625-2337-35
(i)
5, ENTR (TIMING, VIDEO LEVELS).
(j)
Use the arrow keys to highlight CHALLENGE VIDEO:.
(k)
5, ENTR (5.0 V).
Press FUNC, ↑.
(l)
(m)
16, ENTR (GENERAL MEASUREMENTS).
(n)
Use the arrow keys to highlight SOURCE: ENTR (LOW PWR).
(o)
Use the arrow keys to highlight PULSE#:.
(p)
10, ENTR.
(q)
Use the arrow keys to highlight TO PULSE#:.
(r)
36, ENTR.
(3) Set signal generator for an output of 1030 MHz at +10 dBm with external
pulse modulation.
(4) Use the arrow keys to highlight SPACING: and press the ENTR key.
(5) Adjust the oscilloscope channel 1 Volts/Div and vertical position controls for 2 to
4 divisions of vertical deflection with the signal baseline on the center graticule line.
(6) Adjust the oscilloscope horizontal Sec/Div and position control to display 36 pulses.
(7) Measure and record the delay time from the 10th pulse to the 36th pulse on
channel 2 of the oscilloscope.
52