Table 27. Residual Response (100 Hz to 5.8 GHz)
Harmonic Distortion

Calibration Procedure For Spectrum Analyzer, Model 8566B Page Navigation
  53    54    55    56    57  58  59    60    61    62    63  
img
. . . . . .
TB 9-6625-2340-24
(16) Amplitude indicated on TI display will be within limits specified in the first row
of table 28.
(17) Press TI keys as listed in (a) and (b) below:
CENTER FREQUENCY.
(a)
.
(b)
(18) Repeat technique used in (13) (c) and (14) through (17) above for remaining TI
settings in table 28. TI amplitude indicated will be within limits specified in table 28.
Table 28. Residual Response (5.7 GHz to 11.65 GHz)
Test instrument
Center frequency
Displayed amplitude
(GHz)
limit (dBm)
95
6.2
95
7.19
95
8.18
95
9.17
95
10.16
95
11.15
(19) Press TI keys as listed in (a) through (e) below:
START FREQUENCY, 11.6, GHz.
(a)
STOP FREQUENCY, 12.5, GHz.
(b)
VIDEO BW, 3, kHz.
(c)
TRACE A CLEAR WRITE.
(d)
SWEEP SINGLE.
(e)
(20) Wait for completion of sweep.
(21) Press TI MARKER PEAK SEARCH key.
(22) Amplitude indicated on TI display will be within limits specified in table 29.
Table 29. Residual Response (11.6 GHz to 12.5 GHz)
Test Instrument
Displayed
Start
Stop
amplitude limit
frequency
frequency
(dBm)
95
11.6 GHz
12.5 GHz
(23) Press TI keys as listed in (a) through (g) below:
START FREQUENCY, 12.4, GHz.
(a)
STOP FREQUENCY, 18.0, GHz.
(b)
RES BW, 100, kHz.
(c)
VIDEO BW, 3, kHz.
(d)
DISPLAY LINE ENTER, 85, dBm.
(e)
TRACE A CLEAR WRITE.
(f)
SWEEP SINGLE.
(g)
(24) Wait for completion of sweep.
(25) Press TI MARKER PEAK SEARCH key.