TB 9-6625-2344-35
WARNING
HIGH VOLTAGE is used or exposed during the performance of
DEATH ON CONTACT may result if
personnel fail to observe safety precautions.
REDUCE
OUPUT(S) to minimum after each step within the performance
check where applicable.
NOTE
Throughout this bulletin, the term "button" denotes a front
panel pushbutton which must be physically pressed. The term
"key" denotes a button which must be activated by using the TI
mouse.
a. Connect TI mouse to mouse input port on TI rear panel.
b.
Connect TI
keyboard to
keyboard input port on TI
rear panel.
c. Connect TI to appropriate power source.
d. Press TI
button and allow 30 minute warm-up time.
NOTE
Warm up must be preceded by a 2 hour non-operating
temperature stabilization period (if applicable).
e. Using TI mouse, click
key to enable graphical interface.
f. Click UTILITIES menu on top of TI display.
g. From displayed roll down menu, click SELF TEST.
h. In SELF TEST WINDOW, click SELF TEST ∇ key.
i. Click SCOPE SELF TESTS from SELF TEST drop-down list box.
j.
Click START TEST key.
NOTE
If one or more self-tests fail, refer to TM 43-6625-915-40
Chapter 2, Troubleshooting Procedures.
k. Once TI has passed self-tests, in SELF TEST window, click CLOSE key.
NOTE