TB 9-6625-149-50
Table 5. Sweep Timing - Continued
Time-mark
Test instrument
generator
Markers
TIME/CM
setting.
Per/cm.
switch setting
5 MILLISEC
5 mS
1
10 MILLISEC
10 mS
1
20 MILLISEC
10 mS
2
50 MILLISEC
50 mS
1
.1 SEC
.1 S
1
.2 SEC
.1 S
2
.5 SEC
.5 S
1
1 SEC
1S
1
2 SEC
1S
2
5 SEC
5S
1
1Adjust
2Adjust
3Adjust C160C (fig 1). (R)
4Adjust C160E (fig 1). (R)
(4) Position TI controls as listed in (a) through (c) below:
(a) TIME/CM switch to .1 SEC.
(b) HORIZONTAL DISPLAY switch to 5X MAG.
(c) TRIGGER SLOPE switch to +EXT.
(5) Connect TRIGGER OUTPUT of time-mark generator to TI TRIGGER
INPUT, using cable (B4 or B5) and if necessary, adapter (B2).
(7) Position second cycle behind second vertical graticule line with HORIZONTAL
POSITION control. If ninth cycle is not between 7.6 and 8.4 centimeters from second
cycle, perform b(2) below.
(8) Position 13th cycle from end of trace behind second vertical graticule line with
HORIZONTAL POSITION control. If fourth cycle from end of trace is not between 7.6 and
8.4 centimeters from 13th cycle, perform b(3) below.
b. Adjustments
(1) Adjust the respective adjustments listed in table 5 footnotes.
(2) Adjust C364 (fig. 2) for 1 cycle/cm over middle 8 centimeter. (R)
(3) Adjust C384 (fig. 2) for 1 cycle/cm over middle 8 centimeter. (R)
17. External Dc Balance
15