TB 9-6625-149-50
b. Adjustments. Adjust
Z-IN ADJ. R452 (fig. 4) until
amplitude of
waveform is
equal to amplitude recorded in a(6) above.
a. Performance Check. Adjust controls of oscilloscope (A7) and TI for 4 centimeters
of vertical deflection. If leading and trailing edges of waveform are unequal in amplitude,
perform b below.
b. Adjustments. Adjust
L.F. ADJ. R481 (fig. 4) until
leading and trailing
edges of
Figure 4. Current probe amplifier - typical left - interior view (types 131-1 through -4).
a. Performance Check
(1) Turn TI CURRENT/DIV. switch to 1 mAMP.
(2) Turn plug-in (A8) VARIABLE VOLTS/CM control to CALIBRATED.
If
oscilloscope (A7) does not indicate 4 centimeters of vertical deflection, perform b below.
b. Adjustments. Adjust GAIN ADJ.
R464 (fig. 4)
for 4
centimeters of
vertical
deflection on oscilloscope. (R)
20