TB 9-6625-166-24
Table 8. Temperature Accuracy.
Test instrument
Thermometer Reading
(C)
Min (C)
Max (C)
-10
-11.8
-8.2
-2.0
0.0
2.0
350
341.0
359.0
14. Final Procedure
a. Deenergize and disconnect all equipment.
b. Annotate and affix DA label/form in accordance with TB 750-25. If the customer
does not turn in a temperature probe a DA label 163 will be attached stating temperature is
not calibrated.