TB 9-6625-2296-24
Table 2. Minimum Specifications of Equipment Required - Continued
Manufacturer and model
Common name
Minimum use specifications
(part number)
Ac volts:
Fluke, Model 8508A/02
Range: 20 Hz to 25 kHz
(8508A/02)
1 mV to 2.5 V rms
Accuracy: 25 mV or 0.75% <10 kHz
1.25% >10 to 25 kHz
Dc volts:
Range: 4.096 to 35 V dc
Accuracy: (0.0006 %) 0.005%
Range: 50 Hz
(OS-303/G)
Accuracy: <125 ns risetime
Fluke, Model 9500B/3200
Voltage:
(9500B/3200)
Range: 4 mV to 100 V dc
CALIBRATOR
Accuracy: 2.0%
Leveled sine wave:
Markers:
Range: 2 s to 100 ms/div
Accuracy: 0.25%
Weinschel, Model 1870A
POWER SPLITTER
Insertion loss -6dB
(7916839)
Output tracking between ports:
10 MHz to 1 GHz: 0.15 dB
IET Labs, HARS-LX-9-0.001
(HARS-LX-9-0.001)
Accuracy: 1%
RF POWER METER
Bird, Model 4421 (4421) w/
Output: 7.5 to 85 W
Directional power sensors,
Accuracy: (3 %)
Model 4021 and 4022 (4021 and
4022)
Aeroflex, Model 2023B (2023B
Frequency: 1 to 900.15 MHz
OPT2/4/11/122)
Resolution: 1 Hz
Accuracy: 1.125 ppm
Output: 0 to -40 dB
2 to 5 V
Mod Freq: 100 Hz to 19 kHz
FM:
1 to 90 kHz
AM:
30 to 90 %
Common name
Description (part number)
LOCK OUT KEY (7005-7840-500)
EXTENDER CARD
66295 (7010-7839-900)
NONCONDUCTIVE ADJUSTMENT TOOL
Johanson 4192
RF POWER AMPLIFIER
Ophir RF Inc, Model XRF733 (XRF733)
SERIAL INTERFACE CABLE ASSEMBLY
NULL MODEM CABLE
7