TB 9-6625-2332-50
Digitizing oscilloscope
indications
Test instrument
(sec)
settings
Risetime
Falltime
Per setting
Lead setting
Trail setting
Min
Max
Min
Max
le-9
le-9
0.6e-9
1.4e-9
0.6e-9
1.4e-9
1 sec
10e-9
10e-9
8.7e-9
11.3e-9
8.7e-9
11.3e-9
20e-9
20e-9
17.7e-9
22.3e-9
17.7e-9
22.3e-9
100e-9
100e-9
90e-9
110e-9
90e-9
110e-9
100 sec
1e-6
le-6
0.9e-6
1.1e-6
0.9e-6
1.1e-6
10e-6
10e-6
9e.6
11e-6
9e-6
11e-6
10 msec
100e-6
100e-6
90e-6
110e-6
90e-6
110e-6
1e-3
1e-3
0.9e-3
1.1e-3
0.9e-3
1.1e-3
200 msec
10e-3
10e-3
9e-3
11e-3
9e-3
11e-3
(12) Press DISABLE pushbutton (model 9211 output module) to off (red light lit).
(13) Disconnect cable from TI 9211 module OUTPUT.
(14) Connect cable to TI 9215 module OUTPUT.
(16) Press TI pushbuttons as listed in (a) through (h) below:
(a)
CHANNEL B
(b)
Vhigh and
enter 5 from data keyboard and
press ENTER/HZ.
(c)
Vlow and
enter 0 from the
data keyboard and
press ENTER/HZ.
(d)
Lead and
enter 6.5 from data keyboard and
press n/GHz.
(e)
Trail and
enter 6.5 from data keyboard and
press n/GHz.
Per and
enter 1 from data keyboard and
press /MHz.
(f)
(g)
Duty and
enter 50 from data keyboard and
press ENTER/HZ.
(h)
Press DISABLE pushbutton (9215 output module) to on (red light
extinguished).
(18) Verify that the digitizing oscilloscope indicates within the limits listed in table
(20) Verify that the digitizing oscilloscope indicates within the limits listed in table
11 for the
Trail setting.
(21) Set TI to the next Lead, Trail, and Per (if listed) settings listed in table 11.
(22) Repeat (17) through (20) above.
(23) Repeat (21) through (22) above for the remaining Lead, Trail, and Per settings
13