TB 9-6625-2340-24
(14) Press TI SHIFT and TRACE A MAX HOLD keys.
LVL indication, as indicated by TI
annotation, flickers back and forth between .00 and .10 dB.
(16) Press TI SHIFT and TRACE A VIEW keys.
LVL indication, as indicated by TI
annotation, flickers back and forth between .00 and .10 dB.
(18) Press TI SHIFT and TRACE A BLANK keys.
(19) Remove short from between A3A9TP1 to A3A9TP3 (fig. 22). Reconnect 7 (violet)
cable to A4A1J1.
(20) Connect multimeter HI to A4A1TP3 (fig. 21) and multimeter LO to A3A9TP1
(21) Press TI REFERENCE LEVEL key.
(22) Adjust TI DATA knob for a multimeter indication of 2.000 0.001 V dc.
(24) Press TI keys as listed in (a) through (e) below:
SWEEP SINGLE.
(a)
TRACE A CLEAR-WRITE.
(b)
MARKER NORMAL.
(c)
MARKER .
(d)
SWEEP CONT.
(e)
LVL indication, of 100 0.1 dB on TI (R).
(26) Press TI SHIFT and TRACE A MAX HOLD keys.
LVL indication, of 100 0.1 dB on TI (R).
(28) Press TI SHIFT and TRACE A VIEW keys.
LVL indication, of 100 0.1 dB on TI (R).
(31) Disconnect TI RF INPUT from TI CAL OUTPUT.
(32) Press TI keys as listed in (a) through (f) below:
2-22 GHz.
(a)
(b)
(c)
REFERENCE LEVEL, 10, +dBm.
(d)
RES BW, 10, kHz.
(e)
SCALE LIN.
(f)
(34) Adjust A4A2R79 (fig. 24) for 0.0000 0.0005 V dc