(8) Set TI outputs to minimum.
Table 17. Amplitude Modulation External
Measuring receiver indication
TI Output Power
TI Frequency
(dBm)
(GHz)
Min (%)
Max (%)
4
1.5
45.0
55.0
2
2.2
45.0
55.0
2
2.3
45.0
55.0
2
5.0
45.0
55.0
2
8.3
45.0
55.0
2
8.4
45.0
55.0
2
14.0
45.0
55.0
2
20.0
45.0
55.0
-6
23.0
45.0
55.0
-6
26.5
45.0
55.0
-6
30.0
45.0
55.0
b. Adjustments.  Perform paragraph 16 (b) Amplitude Modulation Internal.
After
adjustment, repeat 16 (a) and 17 (a).
18. Final Procedure
a. Deenergize and disconnect all equipment.
b. Annotate and affix DA label/form163 in accordance with TB 750-25 that calibration
was limited as follows:
Harmonics not verified above 24 GHz
Amplitude Modulation not verified above 30 GHz