TB 9-6625-116-24
Table 10. P-P Square Wave to RMS Conversion (1 kHz and 10 kHz).
TI Target Square Wave (V p-p)
800.00 uV
0.39997 mV
1.9000 mv
0.94992 mV
2.3000 mV
1.14990 mV
5.0000 mV
2.49979 mV
6.0000 mV
2.99975 mV
19.000 mV
9.49921 mV
23.000 mV
11.49905 mV
50.000 mV
24.9979 mV
60.000 mV
29.9975 mV
190.00 mV
94.9921 mV
230.00 mV
114.9905 mV
500.00 mV
0.249979 V
600.00 mV
0.299975 V
1.9000 V
0.949921 V
2.3000 V
1.149905 V
5.0000 V
2.49979 V
6.0000 V
2.99975 V
19.000 V
9.49921 V
23.000 V
11.49905 V
50.000 V
24.9979 V
60.000 V
29.9975 V
190.00 V
94.9921 V
(12) Press [WAVE FORM] and [
] (positive square).
(13) Repeat technique of (3)(h) through (k) and (4) through (8) above for targets 1-22
only (1 kHz and 10 kHz). Do not adjust targets 23-44 (30 kHz and 100 kHz).
(14) Press [WAVE FORM] and [
] (negative square).
(15) Repeat technique of (3)(h) through (k) and (4) through (8) above for targets 1-22
only (1 kHz and 10 kHz). Do not adjust targets 23-44 (30 kHz and 100 kHz).
(16) Set TI as listed in (a) and (b) below:
(a) [WAVE FORM]
(b) [
] (symmetrical square)
(17) Repeat technique of (3)(h) through (k) and (4) through (8) above for targets 1-22
only (1 kHz and 10 kHz). Do not adjust targets 23-44 (30 kHz and 100 kHz).
(18) Ensure that the OUTPUT is OFF, then disconnect active head at multimeter,
insert 50 feedthrough termination, and reconnect to multimeter.
14