TB 9-6625-2213-24
Measuring receiver indications
Test instrument
(mV rms)
mV-RANGE-DB
Amplitude
switch settings
settings
settings
(mV)
Min
Max
(dBm)
(MHz)
+13
10
1000
980
1020
+2.55
10
300
294
306
-6.9
10
100
98
102
-17.4
10
30
29.4
30.6
-26.9
10
10
9.8
10.2
-37.4
10
3
2.94
3.06
-46.9
10
1
0.98
1.02
-57.4
10
0.3
0.294
0.306
-66.9
10
0.1
0.098
0.102
+13
60
1000
980
1020
+2.55
60
300
294
306
-6.9
60
100
98
102
-17.4
60
30
29.4
30.6
-26.9
60
10
9.8
10.2
-37.4
60
3
2.94
3.06
-46.9
60
1
0.98
1.02
-57.4
60
0.3
0.294
0.306
-66.9
60
0.1
0.094
0.102
+13
100
1000
960
10401
+2.55
100
300
288
3121
-6.9
100
100
96.0
104.01
-17.4
100
30
28.8
31.21
-26.9
100
10
9.60
10.41
-37.4
100
3
2.88
3.121
-46.9
100
1
0.96
1.041
-57.4
100
0.3
0.288
0.3121
-66.9
100
0.1
0.096
0.1041
+13
200
1000
940
1062
+2.55
200
300
282
3182
-6.9
200
100
94
1062
-17.4
200
30
28.2
31.82
-26.9
200
10
9.4
10.62
-37.4
200
3
2.82
3. 182
-46.9
200
1
0.94
1.062
-57.4
200
0.3
0.282
0.3182
-66.9
200
0.1
0.094
0.1062
+13
375
1000
920
(880)
1080
(1120)
+2.55
375
300
276
(264)
324
(336)
-6.9
375
100
98.2
(88)
108
(112)
-17.4
375
30
27.6
(26.4)
32.4
(33.6)
-26.9
375
10
9.2
(8.8)
10.8
(11.2)
-37.4
375
3
2.76
(2.64)
3.24
(3.36)
-46.9
375
1
0.92
(0.88)
1.08
(1.12)
-57.4
375
0.3
0.276
(0.264)
0.324
(0.336)
-66.9
375
0.1
0.092
(0.088)
0.108
(0.112)
8