TB 9-6625-2259-24
(5) Configure measuring receiver to measure FM deviation with 50 high pass filter
and 15 kHz low pass filters selected. Measuring receiver indication will be within limit
(6) Repeat technique of (3) through (5) above for remaining frequencies listed in
table 6. Measuring receiver indication will be within limit specified in table 6.
Test instrument
F1 M3 display frequency
Measuring receiver
indications
indication limit
(GHz)
(kHz)
0.010
<5.0
0.100
<5.0
1.000
<5.0
1.700
<5.0
(7) Press LEVEL key and set LEVEL display to +10 dBm by pressing 10 with
DATA ENTRY keys and then by pressing GHz/dBm/ SEC DATA ENTRY key.
(8) Press FREQUENCY RANGE CW F1 key and set F1 M3 display to F1 M3
display frequency indications listed in table 7.
(9) Configure measuring receiver to measure frequency and allow measuring
receiver to acquire carrier frequency.
(10) Configure measuring receiver to measure FM deviation with 50 high pass filter
and 15 kHz low pass filters selected. Measuring receiver indication will be within limit
(11) Repeat technique of (8) through (10) above for remaining frequencies listed in
table 7. Measuring receiver indication will be within limit specified in table 7.
Test instrument
F1 M3 display frequency
Measuring receiver
indications
indication limit
(GHz)
(kHz)
3.000
<5.0
4.000
<5.0
5.000
<7.0
6.000
<7.0
12.000
<15.0
17.500
<15.0
b. Adjustments. No adjustments can be made.
13. Maximum Output Power Test
a. Performance Test
(1) Press TI RESET key.
(2) Ensure RF SLOPE control is in OFF position.