CALIBRATION PROCEDURE FOR SPECTRUM ANALYZER
SECTION I. IDENTIFICATION AND DESCRIPTION

Calibration Procedure For Spectrum Analyzer, If, Lf, And Rf Plug-In Units, Models 8552, 8553, 8554, 8555, And 8556 Page Navigation
  1  2  3    4    5    6    7  
img
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TB 9-6625-1914-24
Paragraph
Page
Final procedure ..................................................
14
19
Preliminary instructions ...................................
15
20
Equipment setup................................................
16
20
Scan width accuracy ..........................................
17
20
Tuning dial accuracy and range .......................
18
22
Frequency response ...........................................
19
25
Average noise level (sensitivity) .......................
20
27
Spurious response ..............................................
21
29
Local oscillator stability ....................................
22
30
Final procedure ..................................................
23
32
V.
CALIBRATION PROCESS FOR SPECTRUM
ANALYZER RF PLUG-IN, HEWLETT-
PACKARD, MODEL 8554( )
Preliminary instructions ...................................
24
32
Equipment setup................................................
25
33
Scan width accuracy ..........................................
26
33
Tuning dial accuracy .........................................
27
34
Frequency response ...........................................
28
37
Average noise level (sensitivity) .......................
29
38
Spurious response ..............................................
30
38
Local oscillator stability ....................................
31
40
Final procedure ..................................................
32
41
VI.
CALIBRATION PROCESS FOR SPECTRUM
ANALYZER RF PLUG-IN, HEWLETT-
PACKARD, MODEL 8555( )
Preliminary instructions ...................................
33
42
Equipment setup................................................
34
42
Dial accuracy ......................................................
35
44
Scan accuracy .....................................................
36
45
Noise sidebands .................................................
37
46
Residual responses ............................................
38
47
Sensitivity ..........................................................
39
47
Final procedure ..................................................
40
48
VII.
CALIBRATION PROCESS FOR SPECTRUM
ANALYZER LF PLUG-IN, HEWLETT-
PACKARD, MODEL 8556( )
Preliminary instructions ...................................
41
48
Equipment setup................................................
42
49
Tracking generator amplitude ..........................
43
51
Marker accuracy..........................................
44
53
Scan width accuracy ..........................................
45
54
Center frequency accuracy ................................
46
56
Frequency response ...........................................
47
57
Average noise level ............................................
48
58
2