Table 14. RxDirect Output Continued.
Table 16. Input Level Messages.

Calibration Procedure For Test Set, Control, Model T-36M (90000058) Page Navigation
  24    25    26    27    28  29  30    31    32    33    34  
img
. .
TB 9-4920-460-24
(22) Slowly vary RF reference source frequency 9.5 kHz from 120MHz. TI will track
frequency within 500 Hz throughout.
(23) Set RF reference source for an output of +16 dBm at 120 MHz.
Table 15. RxRamp Output.
TI indications
RF signal source settings
(W)
Frequency settings
Power output
(MHz)
(dBm)
Min
Max
35
-6.5
21
29
45
-3.5
21
29
55
-1.5
21
29
65
+0.5
21
29
75
+0.5
21
29
85
+0.5
21
29
88
+0.5
21
29
108
+0.5
21
29
115
+0.5
21
29
125
+0.5
21
29
135
+0.5
21
29
145
+0.5
21
29
155
+0.5
21
29
165
+0.5
21
29
174
+0.5
21
29
225
+0.5
21
29
235
+0.5
21
29
245
+0.5
21
29
255
+0.5
21
29
265
+0.5
21
29
275
+0.5
21
29
285
+0.5
21
29
295
+0.5
21
29
300
+0.5
21
29
310
+0.5
21
29
320
+0.5
21
29
330
+0.5
21
29
340
+0.5
21
29
350
+0.5
21
29
360
+0.5
21
29
370
+0.5
21
29
380
+0.5
21
29
390
+0.5
21
29
400
+0.5
21
29
(24) TI will display POWER TOO HIGH. Vary RF reference source output from
+16 dBm to -33 dBm. TI will display will be as outlined in table 16.