TB 9-6625-2320-35
(22) Position leveled sine wave generator controls for a 50 MHz, 350 mV output.
(23) Press front-panel Measure key.
(24) Press main-menu High-Low Setup key.
(25) Press side-menu Min-Max key.
(26) Press main-menu Select Measrmnt for Ch1 key.
(27) Press side-menu -more- key until Amplitude appears in the side-menu.
(28) Press side-menu Amplitude key.
(29) Press front-panel SET LEVEL TO 50% key.
(30) Press front-panel CLEAR MENU key.
(31) Position leveled sine wave generator controls for an amplitude
of 3.5
divisions.
(32) Position leveled sine wave generator controls for a 350 mV C1 Ampl readout.
(33) Disconnect cable from CH 1 and reconnect it to CH 1 through X10 attenuator
NOTE
A stable trigger is one that is consistent; that is, one that
results in a uniform, regular display triggered on the
selected slope (positive or negative). This display should not
have its trigger point switching between opposite slopes, nor
should it roll across the screen. At horizontal scale settings
of 2 ms/division and faster, TRIG'D will remain constantly
lighted. It will flash for slower settings.
28